图片 | 型号 | 库存 | 数量 | 规格书 | 系列 | 包装 | 产品状态 | 类型 | 安装类型 | 电流 - 最大值 | 使用区域 | 过载保护 | 连接器 - 交流输入 | 交流输出插座 | 连接器 - 交流输出 | 电压 - 输入 | 外壳材料 | 受保护的媒体线路 | 能量 | 电线长度 | 认证机构 | 特性 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
P48F19M-BU1BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-BU2BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-GN1APDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-GN1BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-GN2APDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-GN2BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-RD1BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-RD2BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-WH1APDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-WH1BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-WH2APDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-WH2BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-YL1BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48F19M-YL2BPDU VERT C13 C19 MONITORED SWTCH |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
P48E04MMS PDU, 415V, 30 AMP, (48)C13, N |
0 |
|
![]() 规格书 |
SmartZone™ | Bulk | Active | PDU (Power Distribution Unit) | Rack, Vertical | 30A | International | Circuit Breaker(s) | NEMA L22-30P | 48 | IEC 320-C13 (48) | 415V | - | - | - | - | CB, CE, EAC, UL | - |
![]() |
P48E24MMS PDU, 208V, (24)C13/C15, (24)C |
0 |
|
![]() 规格书 |
SmartZone™ | Bulk | Active | PDU (Power Distribution Unit) | Rack, Vertical | 60A | International | Circuit Breaker(s) | IEC 60309 3P+E 6h | 48 | C13/C15 (24), C13/C15/C19/C21 (24) | 208V | Metal | RJ45 | - | 10' (3.05m) | CE, EAC | - |
![]() |
P48E05MMS PDU, 415V, 30 AMP, (42)C13, ( |
0 |
|
![]() 规格书 |
SmartZone™ | Bulk | Obsolete | PDU (Power Distribution Unit) | Rack, Vertical | 30A | International | Circuit Breaker(s) | IEC 60309 3P+N+E 6h | 48 | IEC 320-C13 (42), C19 (6) | 415V | - | - | - | - | CB, CE, EAC, UL | - |
![]() |
P48E03MMS PDU, 415V, 30 AMP, (48)C13, I |
0 |
|
![]() 规格书 |
SmartZone™ | Bulk | Obsolete | PDU (Power Distribution Unit) | Rack, Vertical | 30A | International | Circuit Breaker(s) | IEC 60309 3P+N+E 6h | 48 | IEC 320-C13 (48) | 415V | - | - | - | - | CB, CE, EAC, UL | - |
![]() |
P36G33MMSPO PDU, 32AMP, (24)C13, (12)C1 |
0 |
|
![]() 规格书 |
- | Bulk | Active | PDU (Power Distribution Unit) | Rack, Vertical | 30A | International | - | IEC 60309 3P+N+E 6h | 36 | IEC 320-C13 (30), C19 (6) | 415V | - | - | - | - | - | - |
![]() |
P48E20MMS PDU, 415V, 30 AMP, (12)C13, ( |
0 |
|
![]() 规格书 |
- | Bulk | Obsolete | PDU (Power Distribution Unit) | Rack, Vertical | 32A | International | Circuit Breaker(s) | IEC 60309 3P+N+E 6h | 48 | C13/C15 (24), C13/C15/C19/C21 (24) | 415V | - | - | - | 10' (3.05m) | UL | - |