图片 | 型号 | 库存 | 数量 | 规格书 | 系列 | 包装 | 产品状态 | 安装类型 | 线圈电压 | 触点形式 | 触点额定值(电流) | 切换电压 | 特性 | 端接样式 | 工作温度 | 必须动作电压 | 必须释放电压 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
3RT14766SP36CONTACT. AC1: 690A 2NO+2NC F-PLC Siemens |
0 |
|
![]() 规格书 |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 200 ~ 277VAC/DC | 3PST-NO (3 Form A) | 690 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
![]() |
3RT14766SF36CONTACT. AC1: 690A 2NO+2NC F-PLC Siemens |
0 |
|
![]() 规格书 |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 96 ~ 127VAC/DC | 3PST-NO (3 Form A) | 690 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
![]() |
3TC52170AW4CONTACTOR,DC OPER,SIZE 4,48V,2NO Siemens |
0 |
|
![]() 规格书 |
3TC | Box | Active | Chassis Mount | 48VDC | DPST-NO (2 Form A) | 220 A | 750VDC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
![]() |
3TC52170AN4CONTACTOR SIZE 8 2-POLE Siemens |
0 |
|
![]() 规格书 |
3TC | Box | Active | Chassis Mount | 250VDC | DPST-NO (2 Form A) | 220 A | 750VDC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
![]() |
3TC52170AP4CONTACTOR,DC OPER,SIZE 4,230V,2N Siemens |
0 |
|
![]() 规格书 |
3TC | Box | Active | Chassis Mount | 230VDC | DPST-NO (2 Form A) | 220 A | 750VDC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
![]() |
3TC52170AG4CONTACTOR,DC OPER,SIZE 4,125V,2N Siemens |
0 |
|
![]() 规格书 |
3TC | Box | Active | Chassis Mount | 125VDC | DPST-NO (2 Form A) | 220 A | 750VDC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
![]() |
CLMSE04120CONTACTOR LTG M-HELD,100A,4NO,N4 Siemens |
0 |
|
![]() 规格书 |
- | Box | Active | Chassis Mount | 120VAC | 4PST-NO (4 Form A) | 100 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | - | 102 VAC | - |
![]() |
CLMSE04024CONTACTOR LTG M-HELD,100A,4NO,24 Siemens |
0 |
|
![]() 规格书 |
- | Bulk | Active | Chassis Mount | 24VAC | 4PST-NO (4 Form A) | 100 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | - | 20.4 VAC | - |
![]() |
CLMSE04277CONTACTOR LTG M-HELD,100A,4NO,27 Siemens |
0 |
|
![]() 规格书 |
- | Bulk | Active | Chassis Mount | 277VAC | 4PST-NO (4 Form A) | 100 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | - | 235.5 VAC | - |
![]() |
CLMSE04240CONTACTOR LTG M-HELD,100A,4NO,24 Siemens |
0 |
|
![]() 规格书 |
- | Bulk | Active | Chassis Mount | 240VAC | 4PST-NO (4 Form A) | 100 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | - | 204 VAC | - |